91视频

91视频 Release

YASKAWA J1000 Compact AC Drive Series release

New ProductNov 28, 2007

New release of small and simple YASKAWA AC Drive “J1000” series
– Reliability experienced in the small body –

YASKAWA Electric Corporation (President: Koji Toshima) has commercialized YASKAWA AC Drive “J1000” as a new series of small and versatile AC Drives, meeting the needs of the market of AC Drives, small machines which are growing rapidly, and will start the sales from December 21, 2007.
J1000
1锛幪齈urpose of the commercialization
91视频l warming which is caused by the increase in energy consumption has been recognized as a global issue, and ordinary people are also becoming more and more conscious about the countermeasures. People have greater expectations of “versatile AC Drives” in industrial system machinery, too, as energy-saving equipment and the applications has been expanding.
In particular, in the small-sized AC Drive field, a strong demand is growing for miniaturization and cost reduction of AC Drive itself with the demand for the reduction in machinery size.
Against these backgrounds, “J1000” series became commercially available which provides maximum drive more simply and economically than YASKAWA AC Drive “V1000” series released in December 2006, as the first in a new series of next AC Drives.

The commercialization of YASKAWA AC Drive “J1000” series, in which the standard products are RoHS-compliant (the Restriction of Hazardous Substances in Europe) as an environmental measure together with the ultimate miniaturization and user-friendly operations and simplified settings, will meet the growing energy-saving needs.

銆赌

2锛幪齅ain features
(1) Fully equipped with user and environmentally-friendly functions
– Compact Design
Ultra small body and side-by-side installation helps you to design and set up a more compact control panel.
– Easy Operation
Parameters can be set easily in the setup mode. The verify function makes it easy to check those parameters changed from their default values.
– Environmentally Friendly
The standard products are compliant with RoHS (EU’s Restriction of Hazardous Substances). Our product adopts the Swing PWM method that suppresses the electromagnetic noise to eliminate harsh noise.
(2) Supports stable operations “Various approaches to Start, Run, and Stop”
-Easy Start Even in Heavy Duty Rating <Start>
Full-area and fully-automatic torque boost operations generate a high torque, regardless of whether the speed is accelerated / decelerated or constant. Capable of a 100% torque at 1.5 Hz and a 150% torque at 3 Hz under the HD rating.
– Keeps running in the event of a momentary power loss or a change in load or power supply <Run>
Satisfactory stall prevention and speed search functions act in advance to prevent the AC Drive trip from kicking in and to keep the machine running.
– Full Braking Function <Stop>
Overexcitation braking enables emergency braking without the use of a braking resistor. Furthermore, the internal braking transistor provides more powerful braking capabilities only by adding a braking resistor.
(3) Functions and services that bring you safety and assurance
– Environmental Tolerance Design
Various environmentally tolerant products are available to protect the AC Drive against humidity, dust, oil mist, and vibration.
– Hassle-free Maintenance
Makes for a safe check of capacitors or the fan during the maintenance period via the monitor. Also, the engineering tool DriveWizard Plus* lets you unify parameter management on your PC.
– Interactive customer service
Feel free to contact our call center for any inquiries and information about our products. Our specialized engineers will respond you politely with their true opinions.

*An interface unit(option) is necessary to use DriveWizard Plus.

(4) A wide variety of variations with more ease of use
Models that can be connected to a single-phase 100 V commercial power supply are being prepared.*
EMC filter integrated models are being prepared.
Variable resistor unit for frequency setting is being prepared (option).
Remote operation LED operator is being prepared (option).
– Unit for MEMOBUS communication is being prepared (option).
* Under development

銆赌

3锛嶮ain applications

J1000 can be used in various applications. The following equipment is especially applicable.
(1)Compact fans
(2)Compact pumps including feed water and hydraulic pumps
(3)Compact transport equipment including conveyors
(4)Automatic shutters/doors
(5)Food machinery
(6)Agricultural machinery
(7)Health equipment
(8)Compact elevating device
(9)Rotor machine including agitators, centrifuges, and polishing machines

銆赌

4锛嶴ales plan
(1) Series of products
100 V single-phase, 0.2/0.1 to 1.1/0.75 kW: 4 models* in total
200 V three-phase, 0.2/0.1 to 5.5/3.7 kW: 9 models in total
200 V single-phase, 0.2/0.1 to 2.2/1.5 kW: 5 models in total
400 V three-phase, 0.4/0.2 to 5.5/3.7 kW: 7 models in total
*During development
(2) Sales Plan
2008: 30000units/year
2009: 60000units/year
* Values in kW indicate motor kW which can be driven in each case (normal duty rating/heavy load rating).
* For dates to start selling and delivering optional items, please inquire us separately.

銆赌

5锛嶰迟丑别谤蝉
We will exhibit YASKAWA AC Drive “J1000” series at SEMICON Japan 2007 (held at the Makuhari Messe from December 5 to 7, 2007) hosted by SEMI JAPAN.
锛籇escription of the terms锛
1. Normal duty (ND) rating / heavy duty (HD) rating
Rating corresponding to relatively light-load machines, such as fans and pumps, is called normal duty (ND) rating. In comparison with this, rating corresponding to heavy-load machines, such as conveyors and small-sized elevating devices, is called heavy duty (HD) rating. When an AC Drive has both ratings, an optimum capacity corresponding to each load can be selected.
2. EU’s RoHS Directive
Standing for the restriction of the use of certain hazardous substances in electrical and electronic equipment, this directive prohibits electronic equipment sold in Europe from containing specific hazardous substances such as lead. Control devices such as AC Drives are exempt from its regulation as of today, but some countermeasures are desired from the viewpoints of the reduction of environmentally harmful substances.
3. Swing PWM control systems
In normal PWM control systems, harsh metallic noises occur when the carrier frequency is low, and electromagnetic noise increases when it is high. Our original SwingPWM system reduces harsh noises by making the carrier frequency variable and not increasing it to make the noises disappear in those at the plant.
锛籖别蹿别谤别苍肠别蝉锛
Standard specifications
200 V class (three-/single- phase)
Models Three-phase CIMR-JA2A
****
0001 0002 0004 0006 0008 0010 0012 0018 0020
Single-phase CIMR-JABA
**** *1
0001 0002 0003 0006 0010
Maximum applicable motor output*2 ND
rating
0.2 0.4 0.75 1.1 1.5 2.2 3 3.7 5.5
ND
rating
0.1 0.2 0.4 0.75 1.1 1.5 2.2 3 3.7/4
Rated output current A ND rating*3 1.2 1.9 3.5
(3.3)
6 8 9.6 12 17.5 19.6
HD
rating
0.8*4 1.6*4 3*4 5*4 6.9*5 8*5 11*5 14*5 17.5*5
Rated voltage/frequency For three-phase power source:
Three-phase 200 to 240V, 50/60 Hz
For single-phase power source:
Single-phase 200 to 240V, 50/60Hz
400 V class (three-phase)

Model CIMR-JA4A鈻♀枴鈻♀枴

0001 0002 0004 0005 0007 0009 0011

Maximum applicable motor output*2 kW

ND rating

0.4 0.75 1.5 2.2 3 3.7 5.5

ND rating

0.2 0.4 0.75 1.5 2.2 3 3.7/4

Rated output current A

ND rating*3

1.2 2.1 4.1 5.4 6.9 8.8 11.1

HD rating*5

1.2 1.8 3.4 4.8 5.5 7.2 9.2

Rated voltage/frequency

Three-phase 380 to 480V, 50/60Hz
Common specifications

Items

Specifications

Control system

V/f control without PG

Speed control range

1:20 to 1:40

Overload capacity

ND rating:120% of the rated output current: 60 sec.
HD rating:150% of the rated output current: 60 sec.
(Applications which receive loads repeatedly require derating.)

Input-output terminal

Five digital inputs, one digital output
0-10 V / 4-20 mA analog input:1, 0-10 V analog output: 1

*1锛 AC Drives with a single-phase power source input has three-phase output on the output side. A single-phase motor cannot be used.
*2锛 Maximum applicable motor outputs indicate those of YASKAWA’s standard four-pole, 60Hz, and 200/400 V motors.
To select the capacity strictly, select a model so that it exceeds the motor’s rated current at the rated output current.
*3锛 The values at the carrier frequency of 2 kHz. To increase the carrier frequency, the current needs to be reduced.
*4锛 The values at the carrier frequency of 10 kHz. To increase the carrier frequency, the current needs to be reduced.
*5锛 The values at the carrier frequency of 8 kHz. To increase the carrier frequency, the current needs to be reduced.
External dimensions
Voltage class AC Drive model
颁滨惭搁-闯础鈻♀枴鈻♀枴
External dimensions (mm) Dimensions
W H D
200V
Single-phase
2A0001 68 128 76 1
2A0002 68 128 76 1
2A0004 68 128 108 1
2A0006 68 128 128 1
2A0008 108 128 129 2
2A0010 108 128 129 2
2A0012 108 128 137.5 2
2A0018 140 128 143 2
2A0020 140 128 143 2
200V
three-phase
BA0001 68 128 76 1
BA0002 68 128 76 1
BA0003 68 128 118 1
BA0006 108 128 137.5 2
BA0010 108 128 154 2
400V
dimensions
4A0001 108 128 81 2
4A0002 108 128 99 2
4A0004 108 128 137.5 2
4A0005 108 128 154 2
4A0007 108 128 154 2
4A0009 108 128 154 2
4A0011 140 128 143 2

銆赌

[Contact]

YASKAWA Electric Corporation
Drives Division, Marketing Department, Marketing Section
Manager
Naoto Taniguchi
Tel: + 81-930-25-2548
Fax: +81-930-25-3431